|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
60W Dual Output Switching Power Supply Features : D-60 series Universal AC input/Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on Fixed switching frequency at 54KHz 2 years warranty SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 4) D-60A CH1 5V 4A 0.3 ~ 6A 56W 150mVp-p 6.0% 1.0% 4.0% 800ms, 50ms / 115VAC at full load 10ms/115VAC at full load 120 ~ 370VDC CH2 12V 3A 0.2 ~ 4A D-60B CH1 5V 3A 0.3 ~ 6A 58W 75mVp-p CH1 : 4.75 ~ 5.5V 2.0% 0.5% 0.5% 150mVp-p 5.0% 0.5% 4.0% CH2 24V 1.8A 0.2 ~ 2.2A RIPPLE & NOISE (max.) Note.2 75mVp-p CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 0.5% 0.5% 300ms, 50ms / 230VAC 80ms/230VAC 85 ~ 264VAC 47 ~ 63Hz 73% 2A/115VAC 1A/230VAC COLD START 20A/115VAC <3.5mA / 240VAC 76% 40A/230VAC 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. 5V : 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed. -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 0.03%/ , 10 ~ 95% RH (0 ~ 50 ) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012, UL60950, TUV EN60950 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 301.2K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) 0.54Kg; 24pcs/13.8Kg/0.75CUFT ) MTBF OTHERS NOTE DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:D-60-SPEC 2005-09-13 60W Dual Output Switching Power Supply Mechanical Specification D-60 Case No. 901 series Unit:mm 152.5 7 1 9.5 2 3 4 5 8.2 6 7 65 3.5 84.5 2 -M 3 3 .5 4.5 24 78 159 6.5 150 9 18.5 9 22 117 Terminal Pin. No Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 6,7 Assignment DC OUTPUT +V2 DC OUTPUT +V1 DC OUTPUT COM Output Derating Static Characteristics (B) Ta=25 100 25 5.2 28.5 M3 18 38 3- 3.5 97 OUTPUT VOLTAGE (V) 24 23 22 21 20 19 5.0 250 80 +24V 4.8 4.6 4.4 4.2 4.0 200 150 100 60 40 20 +24V +5V 60 80 100 120 140 160 180 200 220 240 260 50 25 -10 -10 0 0 10 20 30 40 50 45 60 55 (VERTICAL) (HORIZONTAL) AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:D-60-SPEC 2005-09-13 OUTPUT RIPPLE (mVp-p) 3 .5 300 +5V LOAD (%) 120W Dual Output Switching Power Supply Features : AC input range selected by switch D-120 series Protections:Short circuit/Over load/Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 28KHz 2 years warranty SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD TIME VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE D-120A CH1 5V 12A 2 ~ 12A 120W 120mVp-p 6.0% 1.0% 5.0% CH2 12V 5A 0.5 ~ 5A D-120B CH1 5V 6A 2 ~ 10A 126W 60mVp-p 2.0% 0.5% 0.5% 248 ~ 370VDC 80% 150mVp-p 7.0% 1.0% 6.0% CH2 24V 4A 0.4 ~ 4A RIPPLE & NOISE (max.) Note.2 60mVp-p CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 0.5% 0.5% 200ms, 50ms, 20ms at full load 88 ~ 132VAC/176 ~ 264VAC selected by switch 47 ~ 63Hz 78% 2.8A/115VAC 1.6A/230VAC COLD START 35A <3.5mA / 240VAC 105 ~ 135% rated output power Protection type : Shut down o/p voltage, re-power on to recover CH1:5.75 ~ 6.75VDC Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 272.8K hrs min. MIL-HDBK-217F (25 ) 199*110*50mm (L*W*H) 0.82Kg; 16pcs/14.2Kg/0.95CUFT OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:D-120-SPEC 2004-11-30 120W Dual Output Switching Power Supply Mechanical Specification 192 5 100 172 D-120 Case No. 906 series Unit:mm 1 9.5 2 3 4 110 5 6 8.2 5-M3 7 37 8 3.5 199 6.5 12 3.5 159 25 20 3M 3 6 190.5 1 6.5 50 20 Terminal Pin. No Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5,6 7,8 Assignment DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1 Derating Curve 2 4.5 3 .5 Static Characteristics(B) Ta=25 97 6 100 25 24 23 22 21 20 19 0 0 10 20 30 40 50 45 60 55 (VERTICAL) (HORIZONTAL) 5.2 5.0 4.8 4.6 4.4 4.2 4.0 80 OUTPUT VOLTAGE (V) +5V 250 200 150 60 +24V 40 100 50 20 +5V 25 -10 -10 60 120 85 170 90 180 95 190 100 200 105 210 110 220 115 230 120 240 125 250 130 260 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:D-120-SPEC 2004-11-30 OUTPUT RIPPLE (mVp-p) +24V 300 LOAD (%) |
Price & Availability of D-60B |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |